{"product_id":"bullard-hc2400-hot-cold-air-control-tube-with-belt-1-4-industrial-interchange-supplied-air-respirators","title":"Bullard HC2400 Hot\/Cold Air Control Tube with Belt – 1\/4\" Industrial Interchange – Supplied-Air Respirators","description":"\u003ch2\u003e\u003cspan\u003eBullard HC2400 Hot\/Cold Air Control Tube with Belt – 1\/4\" Industrial Interchange\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eImprove operator comfort during abrasive blasting and industrial coating operations with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egenuine Bullard HC2400 Hot\/Cold Air Control Tube Assembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible Bullard supplied-air respirator systems, the HC2400 uses compressed breathing air to provide temperature adjustment for improved comfort during demanding industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeaturing a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/4\" industrial interchange quick-disconnect nipple\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this assembly includes a belt for convenient waist-mounted positioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bullard HC2400 is an excellent choice for operators working in environments where temperature control can make extended blasting and coating operations more comfortable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Bullard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel \/ Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e HC2400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Hot\/Cold Air Control Tube\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Breathing-Air Temperature Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuick-Disconnect Connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/4\" Industrial Interchange Nipple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAir Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible Compressed Breathing-Air System\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Belt-Mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBelt Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supplied-Air Respirator Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eExploded Parts Diagram References:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Items #15 and #17\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuantity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e One Assembly with Belt\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures \u0026amp; Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine Bullard HC2400 air-control assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot\/cold breathing-air temperature control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHelps improve operator comfort in varying working conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1\/4\" industrial interchange quick-disconnect nipple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes belt for convenient waist-mounted operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible Bullard supplied-air respirator systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for replacing worn, damaged, or malfunctioning air-control assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUseful for abrasive blasting and industrial coating applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHot and Cold Breathing-Air Temperature Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard HC2400\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to provide temperature adjustment for breathing air delivered to a compatible supplied-air respirator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsing compressed air and a vortex-based temperature-control process, the assembly can provide temperature-conditioned airflow without requiring an electrical connection at the tube.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes it useful in environments where operators may benefit from warmer or cooler supplied air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Temperature-control performance depends on the incoming air temperature, pressure, airflow, and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HC2400 does not filter, purify, or remove contaminants from the breathing-air supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDesigned for Demanding Industrial Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOperators wearing supplied-air blasting helmets and protective equipment can experience uncomfortable temperatures during extended work periods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bullard HC2400 helps address operator comfort in applications such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial abrasive blasting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStructural steel surface preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShipyard and marine maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBridge restoration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTank and vessel blasting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial spray painting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial sandblasting operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial coating and surface preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e1\/4\" Industrial Interchange Quick-Disconnect\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe HC2400 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/4\" industrial interchange quick-disconnect nipple\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for connection to compatible compressed breathing-air supply equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOriginal Bullard air-control model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequired quick-disconnect fitting profile\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible breathing-air supply hose\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRespirator model and approved configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequired operating pressure and airflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvailable compressed-air capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature-control assemblies may require more compressed air than standard constant-flow devices.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Verify that the air supply meets Bullard's requirements for the HC2400 and the complete respirator system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for approved Bullard supplied-air respirator configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePotential applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBullard 88VX Series Abrasive Blasting Respirators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible Bullard Type CE Supplied-Air Blasting Helmets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOther Bullard supplied-air respirators specifically approved for use with the HC2400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility must be confirmed against Bullard's respirator and air-control instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe HC2400 should not be substituted for an F30, F35, or other air-control assembly unless Bullard approves that configuration.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Reasons for Replacement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting temperature-control tube is damaged\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature adjustment no longer functions properly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuick-disconnect nipple is worn or damaged\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAir leakage at the assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting air-control tube is missing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacing worn equipment during respirator maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstalling a manufacturer-approved temperature-control configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eExploded Parts Diagram References\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDIAGRAM ITEMS #15 AND #17\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis listing includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard HC2400 Hot\/Cold Tube Assembly with Belt\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, corresponding to Items #15 and #17 in the applicable exploded parts diagram.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOther components shown in the diagram are not included unless specifically listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0915\/9358\/files\/Bullard-88-LD.jpg?v=1613543195\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuantity 1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Genuine Bullard HC2400 Hot\/Cold Air Control Tube Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuantity 1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Belt\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eConnection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/4\" Industrial Interchange Quick-Disconnect Nipple\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRespirator helmet, breathing tube, compressed-air supply hose, compressor, breathing-air filtration equipment, and other accessories are sold separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Breathing-Air Safety Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe Bullard HC2400 is a breathing-air temperature-control component, not an air purifier or carbon monoxide removal device.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe compressed breathing-air source must meet applicable respiratory protection requirements, including OSHA 29 CFR 1910.134.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse only manufacturer-approved breathing-air hoses, fittings, and components in the respirator configuration specified by Bullard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFollow Bullard's instructions for operating pressure, airflow, total hose length, and approved component combinations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNever substitute ordinary shop-air hoses or unapproved pneumatic fittings for breathing-air equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNeed Bullard breathing-air hoses, temperature-control tubes, filters, or 88VX helmet replacement parts? Contact us with your equipment model or part number. We'll help you identify the correct components for your system.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ST Sales","offers":[{"title":"Default Title","offer_id":51011380609122,"sku":"HC2400","price":811.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/9358\/files\/HC2400_3Q_H__61550.jpg?v=1794497433","url":"https:\/\/paintingequip.com\/products\/bullard-hc2400-hot-cold-air-control-tube-with-belt-1-4-industrial-interchange-supplied-air-respirators","provider":"ST Sales","version":"1.0","type":"link"}