{"product_id":"bullard-gvx2830-genvx-supplied-air-sandblasting-helmet-28-cape-f30-constant-flow-type-ce","title":"Bullard GVX2830 GenVX Supplied-Air Sandblasting Helmet – 28\" Cape, F30 Constant Flow, Type CE","description":"\u003ch2\u003e\u003cspan\u003eBullard GVX2830 GenVX Supplied-Air Sandblasting Helmet – 28\" Cape with F30 Constant Flow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard GVX2830 GenVX Supplied-Air Sandblasting Respirator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines respiratory protection, head protection, and high-impact face protection in a modern helmet designed for demanding industrial abrasive blasting applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis Type CE continuous-flow supplied-air respirator configuration includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard 28VX 28-inch cape\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eF30 constant-flow air-control assembly with a 1\/4\" industrial interchange quick-disconnect connection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for professional sandblasting contractors, industrial maintenance departments, shipyards, and surface preparation facilities, the GenVX provides a complete helmet and air-control configuration for connection to a compatible compressed breathing-air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Bullard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel \/ Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e GVX2830\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRespirator Series:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e GenVX (GVX)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supplied-Air Abrasive Blasting Respirator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRespirator Classification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e NIOSH Type C and CE, Continuous Flow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCape Model:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 28VX\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCape Length:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 28 Inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAir-Control Assembly:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Bullard F30 Constant Flow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuick-Disconnect Connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/4\" Industrial Interchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAssigned Protection Factor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1,000 (Third-Party Tested; see safety information)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHead Protection Standard:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ANSI\/ISEA Z89.1-2014, Type I, Class C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFace Protection Standard:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ANSI\/ISEA Z87.1-2015, Z87+ High Impact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAir Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible Compressed Breathing-Air System\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eNIOSH Approval Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Bullard GenVX respirator family is associated with the following NIOSH approval numbers supplied by the manufacturer:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0489\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0491\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0492\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0493\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0494\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0495\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTC-19C-0496\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Individual NIOSH approvals apply to specific respirator configurations. The applicable approval for GVX2830 must be confirmed using Bullard's approval label and approved component matrix.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures \u0026amp; Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine Bullard GenVX supplied-air abrasive blasting respirator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType CE continuous-flow respiratory protection configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes 28-inch Bullard 28VX cape\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes F30 constant-flow air-control assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1\/4\" industrial interchange quick-disconnect connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThird-party-tested APF of 1,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eANSI Type I, Class C head protection classification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eANSI Z87+ high-impact face protection classification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for industrial abrasive blasting and surface preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with specified Bullard compressed breathing-air equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eModern GenVX Respirator Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard GenVX\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to provide respiratory, head, and face protection during abrasive blasting operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts supplied-air design delivers breathing air from a compatible external source through the approved breathing-air hose and air-control assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe helmet is intended to help protect the operator while working in environments where abrasive dust and airborne contaminants may be present.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe complete respirator must be properly assembled, inspected, and operated according to Bullard's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBullard 28VX 28-Inch Cape\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis GVX2830 configuration includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard 28VX 28-inch cape\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe cape extends below the helmet to provide coverage around the operator's neck, shoulders, and upper torso.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is an integral part of the specified respirator configuration and must be installed and secured according to Bullard's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eF30 Constant Flow Air-Control Assembly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe included \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBullard F30 Constant Flow Assembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides the specified airflow-control connection for this respirator configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeatures include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConstant-flow air-control design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1\/4\" industrial interchange quick-disconnect connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible compressed breathing-air systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe F30 must be used with the approved breathing-air supply hose and within the operating-pressure range specified by Bullard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe F30 is not interchangeable with the F35 low-pressure free-air pump assembly.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAssigned Protection Factor (APF) of 1,000\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe GenVX respirator family has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethird-party-tested Assigned Protection Factor of 1,000\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, according to the supplied product specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis performance information is relevant to respiratory protection program planning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The third-party-tested APF does not automatically establish an OSHA-assigned protection factor of 1,000 for every workplace. Under OSHA 29 CFR 1910.134, the applicable assigned protection factor depends on respirator classification, configuration, and regulatory requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEmployers must determine the appropriate protection factor and respirator selection under their respiratory protection program.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHead and Face Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe GenVX is specified with the following protection classifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHead Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eANSI\/ISEA Z89.1-2014\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType I\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClass C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eType I addresses protection from impacts to the top of the head. Class C does not provide electrical insulation protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFace Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eANSI\/ISEA Z87.1-2015\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eZ87+ High-Impact Face Protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese classifications apply to the specified helmet assembly and must be maintained through the use of appropriate approved components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial abrasive blasting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStructural steel surface preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShipyard and marine maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBridge restoration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTank and vessel blasting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial coating preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial sandblasting operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeavy equipment surface preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBullard GVX2830 GenVX Respirator Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBullard GenVX Supplied-Air Sandblasting Helmet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBullard 28VX 28-Inch Cape\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBullard F30 Constant Flow Air-Control Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1\/4\" Industrial Interchange Quick-Disconnect Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eBreathing-air supply hose, compressor, breathing-air filtration equipment, carbon monoxide monitoring equipment, and other accessories are not specified as included and should be ordered separately as required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Breathing-Air Safety Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Bullard GVX2830 is a supplied-air respirator and requires an appropriate external breathing-air source.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompressed breathing air must meet applicable quality requirements, including OSHA 29 CFR 1910.134.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse only Bullard-approved breathing-air hoses, air-control assemblies, and other components for the specific NIOSH-approved respirator configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBreathing-air filtration alone does not necessarily remove carbon monoxide. Appropriate air-quality controls and monitoring must be provided as required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFollow Bullard's instructions for operating pressure, airflow, hose length, inspection, maintenance, and respirator use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe respirator must be used under an appropriate workplace respiratory protection program.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNeed Bullard GenVX breathing-air hoses, filters, air-control assemblies, or replacement parts? Contact us with your equipment model or part number. We'll help you identify the correct components for your application.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ST Sales","offers":[{"title":"Default Title","offer_id":51018656448610,"sku":"GVX2830","price":783.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/9358\/files\/GVX2830__67975.webp?v=1794594779","url":"https:\/\/paintingequip.com\/products\/bullard-gvx2830-genvx-supplied-air-sandblasting-helmet-28-cape-f30-constant-flow-type-ce","provider":"ST Sales","version":"1.0","type":"link"}